Maintenance work on the carrier
7.16 Central lubrication system
09.03.2018
Maintenance manual 3 302 744 en 7 - 119
GMK5250L
7.16 Central lubrication system
7.16.1 Checking the level
Grease, spare
parts, tools
– Filling pump from the tool set.
Prerequisites – The parking brake must be engaged.
Checking the level
• Check the level in the grease container (1).
The grease level must be near the max.
mark.
If it is below the min. mark, the level is too
low.
If the level is too low:
• Add more grease; à p. 7 - 120.
s
W
Lubricating
grease
Designation to
DIN 51502
Specification
Classification
GROVE part no.
Grease KP - 1K - 50 DIN 51825 03233369