Maintenance work on the superstructure
8.6 Hydraulic system
8 - 34 3 302 744 en Maintenance manual
GMK5250L
09.03.2018
8.6.5 Cleaning the magnetic rods
Spare parts and
tools
– Receptacle, approx. 5 l (1.5 gal); à p. 2 - 4.
Prerequisites – The truck crane must be standing on a level surface.
– The engine must be switched off and secured against unauthorised use;
à p. 2 - 3.
– During the first 100 operating hours: clean the magnetic rod once a week.
M 3
Designation Quantity GROVE part no.
For oil filter 1:
Filter 1 04156358
Packing set 1 04165792
O
Risk of environmental damage due to leaking consumables.
Always let consumables drain into suitable receptacles. Wipe up any con-
sumables that have leaked.
Store/dispose of consumables and any soaked equipment properly.
Ask about the applicable regulations.