Maintenance work on the superstructure
8.13 Air conditioning system
09.03.2018
Maintenance manual 3 302 744 en 8 - 81
GMK5250L
8.13 Air conditioning system
8.13.1 Checking the air conditioning system
• Check the air-conditioning system in the same way as when checking it on
the carrier;
à Checking the air conditioning system, p. 7 - 131.
8.13.2 Cleaning the condenser fins
Depending on the power of the air-conditioning system (3 KW or 6 KW),
different condensers are installed (type A or B).
• Switch the air conditioning system off.
• Clean the condenser fins (1) with com-
pressed air.
M 1
M 1
S
Risk of damage to the condenser.
Do not use a high pressure cleaner or steam jet cleaner. The powerful jet
may damage the fins. Use only compressed air for cleaning.