Maintenance work on the carrier
7.5 Exhaust system with exhaust emission control
7 - 36 3 302 744 en Maintenance manual
GMK5250L
09.03.2018
Check the
following
• Check the exhaust pipes (2) from the
engine (1) to the silencer (3) for damage.
The exhaust pipes (2) may not have any
holes or cracks.
• Check that the area around the exhaust
pipes is free of loose components which
could burn by coming into contact with the
hot exhaust system.
• Check the filler neck for injecting AdBlue for
external damage.
After checking
• Start the engine.
• Check the AdBlue system gauge on the display in the driver's cab;
à p. 7 - 34.
• Monitor, if exhaust gases leak from possibly damaged places in the
exhaust system.
• Switch off the engine.
If you discover any damage
Have any damaged parts of the exhaust system replaced immediately by
Manitowoc Crane Care or an authorised GROVE dealer.
G
Risk of burns if the exhaust system is hot.
During operation, the exhaust system heats up to 400 °C (750 °F). Wear
suitable gloves and wait until the exhaust system has cooled down. Make
sure not to touch any hot parts.

Table of Contents

Other manuals for Manitowoc Grove GMK 5250L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK 5250L and is the answer not in the manual?

Manitowoc Grove GMK 5250L Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK 5250L
CategoryConstruction Equipment
LanguageEnglish

Related product manuals