Maintenance work on the carrier
7.15 Hydraulic system
09.03.2018
Maintenance manual 3 302 744 en 7 - 109
GMK5250L
Dispatch the oil
sample to the
laboratory
Manitowoc Crane Care gives you the opportunity to have the oil sample ana-
lysed at our contracted laboratory. A delivery note and a protective mailing
bag are available along with the sample containers (GROVE part no.
03141012). You will get the laboratory analysis via the Internet in a short
time.
• Label the sample container prior to dispatch with
– the truck crane serial number,
– the date of sampling,
– the number of operating hours since the last oil change and
– the sampling location (e.g. gauge port on a control block).
• Have the following properties of the oil sample determined by the labora-
tory
– the viscosity,
– the viscosity index,
– the contamination,
– the water content.
Determining the
quality of the oil
• Compare the laboratory analysis with the limit values and carry out the
specified measures if necessary.
Viscosity limit values
– Viscosity ISO-VG 32 in accordance with DIN 51524 Part 2.
– Viscosity index V
i
≥ 150.
If one of these limit values has been reached/fallen short of:
• Carry out an oil change; à p. 7 - 111.
Contamination limit value
– Contamination according to NAS 1638 class 7 or ISO 4406:1999
code 18/16/13 (purity class).
If this limit value has been reached/exceeded:
• Replace the filters of the hydraulic system; à p. 7 - 115.
• Have the hydraulic oil cleaned with a mobile filter unit until the required
cleanliness class is achieved.
Water content limit value
– Water content ≤ 100 ppm.
If this limit value has been reached/exceeded:
• Have the hydraulic oil cleaned with a mobile water separator until the
water content is clearly below the limit value.

Table of Contents

Other manuals for Manitowoc Grove GMK 5250L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK 5250L and is the answer not in the manual?

Manitowoc Grove GMK 5250L Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK 5250L
CategoryConstruction Equipment
LanguageEnglish

Related product manuals