Maintenance work on the carrier
7.15 Hydraulic system
09.03.2018
Maintenance manual 3 302 744 en 7 - 117
GMK5250L
Changing filters
3 and 4
• Remove the receptacle (1).
• Place the filter in a receptacle.
• Change the filter (2).
• Replace any defective parts, where neces-
sary.
• Fill the receptacle with clean oil.
• Put the receptacle on and tighten it.
• Change the filter on the opposite side in the
same way.
O
Risk of damage to the environment from filter residues.
Store used hydraulic oil filter inserts in suitable receptacles and have them
disposed of properly by qualified personnel.