EasyManuals Logo

Manitowoc Grove GMK 5250L Maintenance Manual

Manitowoc Grove GMK 5250L
354 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #254 background imageLoading...
Page #254 background image
Maintenance work on the superstructure
8.5 Slewing bearing
8 - 26 3 302 744 en Maintenance manual
GMK5250L
09.03.2018
First lubrication
• Remove the plate (1).
• Remove the old grease from all the gear
teeth (2).
• Apply a thin layer of new grease to all the
gear teeth and allow it to penetrate for
approx. 10 minutes.
• Apply a second, thicker layer of grease and
allow it to penetrate for approx. 30 minutes.
• Attach the plate.
Subsequent lubrication
• Remove the plate (1).
• Apply new grease to all the gear teeth (2).
• Allow it to penetrate for approx. 30 minutes.
• Attach the plate.