EasyManuals Logo
Home>Manitowoc>Construction Equipment>Grove GMK 5250L

Manitowoc Grove GMK 5250L Maintenance Manual

Manitowoc Grove GMK 5250L
354 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #274 background imageLoading...
Page #274 background image
Maintenance work on the superstructure
8.6 Hydraulic system
8 - 46 3 302 744 en Maintenance manual
GMK5250L
09.03.2018
Establishing the
operating
conditions
After having changed the oil filters and topping up the oil, you must
re-establish the operating conditions.
Opening the valve
• Open the valve – lever (1) parallel to the line.
• Start the engine.
• Carry out all hydraulic functions several times to remove any air in the
system.
• Check that none of the oil filters is leaking.
• Check the oil level through the inspection glass on the hydraulic oil tank.
Top up oil, if necessary;
à p. 8 - 45.
S
Risk of damage to the hydraulic pumps.
Open the valve prior to starting the engine.
This prevents damage to the hydraulic pumps.

Table of Contents

Other manuals for Manitowoc Grove GMK 5250L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK 5250L and is the answer not in the manual?

Manitowoc Grove GMK 5250L Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK 5250L
CategoryConstruction Equipment
LanguageEnglish

Related product manuals