Maintenance overview
5.4 Measures required for winch monitoring
5 - 28 3 302 744 en Maintenance manual
GMK5250L
09.03.2018
Sample table to determine the remaining theoretical service life on winch no. 1 (main hoist winch)
Crane type: GMK 3045
Work number: 3045 42 06
First commissioned on: 10. 06. 1990
Serial number of the winch in accordance with the model plate: 13 301
Last general overhaul performed on:
........................
Winch design data (see operating manual):
Engine group: M 3
Load spectrum: Q1 (L1)
Factor of the load spectrum: Km = 0.125
Theoretical service life: D = 3,200 h
IMPORTANT:
A general overhaul is to be performed every 10 years.
For alternative provision, refer to section 5.4.2, p. 5 - 25.
General overhaul performed on.......................................
Inspection
interval no.
(max.
1 year)
Date of first
commis-
sioning/date
of inspec-
tion
Operating
conditions
since the
last inspec-
tion
Factor of the
load spec-
trum
Crane oper-
ating hours
(complete)
Superstruc-
ture operat-
ing hours
Superstruc-
ture operat-
ing hours
since the
last inspec-
tion
Winch oper-
ating hours
Operating
hours T
i
of the
winch since the
last inspection
Used propor-
tion S
i
of the-
oretical service
life D:
Remaining the-
oretical service
life
D
i
= D
i-1
- S
i
Name of the
expert
Signature Comment Name of the
approved
inspector
Signature
”i” Km
i
[h] [h] [h] [h] [h] [h] [h]
0(*) 10. 6. 90 0 3,200
1 5. 6. 91 L1 0.125 160 160 160 3,040 Müller
2 20. 5. 92 L3 0.5 640 480 1,920 11,20 Huber
3 18. 5. 93 L2 0.25 940 300 600 520 Schmitz
S
i
= Used proportion of theoretical service life since the last inspection
D
i
= Remaining theoretical service life
D
i - 1
= Remaining theoretical service life after the previous inspection
Km = Load spectrum factor used as the basis for winch calculation.
This factor is given in the operating manual.
Km
i
= Load spectrum factor in inspection interval i according to section 2.1
T
i
= Effective operating hours in inspection interval i according to section 2.2
(*) Copy the last line of the previous page to the following page.

Table of Contents

Other manuals for Manitowoc Grove GMK 5250L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK 5250L and is the answer not in the manual?

Manitowoc Grove GMK 5250L Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK 5250L
CategoryConstruction Equipment
LanguageEnglish

Related product manuals