Calculation of Projected Wind Area (Ap):
Determining Wind Drag Coefficient (Cd)
Table 2-2 shows the typical Shapes and corresponding Wind
Drag Coefficient (Cd) values.
If the exact Wind Drag Coefficient of a shape is not known
,
use the maximum value of the shape’s range
(Table 2-2).
If the wind drag coefficient of the load cannot be estimated or
determined, it shall be assumed that (Cd)=2.4.