ELECTRICAL SYSTEM MLC165-1 SERVICE/MAINTENANCE MANUAL
3-34
Published 05-26-17, Control # 238-02
Table 3-4. Digital Input Reference
CAN Packet
Number
Item Description
(Node Number)
CAN Packet
Number
Item Description
(Node Number
)
CAN36-1-1 Free Fall Safety Switch Left Pedal CAN92-3-8 Drum 0 Park Switch
CAN36-1-2 Self Assembly Cylinder Retract CAN92-3-16 Rear Drum (Drum 2) Park Switch (N1)
CAN36-1-4 Self Assembly Cylinder Extend CAN92-3-64 Travel Park Switch (N1)
CAN36-1-8 Free Fall Safety Switch Right Pedal CAN92-3-128 Mast Cylinders Retract Switch (N1)
CAN36-1-16 Air Conditioning - On (N2) CAN92-4-1 Display Enter Switch (N1)
CAN36-1-32 Cab Tilt - Down (N2) CAN92-4-2 Confirm Switch (N1)
CAN36-1-128 Seat Safety Switch (N2) CAN92-4-4 Limit Bypass Switch (N1)
CAN36-2-16 Cab Tilt - Up (N2) CAN92-4-8 Display Scroll Up Switch (N1)
CAN36-2-32 Drum Speed CAN92-4-32 Display Scroll Down Switch (N1)
CAN36-2-64 Travel Speed (N2) CAN92-4-128 Free Fall Enable Switch Drum 1
CAN38-1-14 Swing Limit Right CAN92-5-1 Boom Hinge Pins Disengage
CAN38-1-8 Swing Limit Left CAN92-5-2 Mast Cylinders Extend Switch
CAN38-1-64 Max Boom Angle Limit CAN92-5-4 DPF Regen Inhibit (N1)
CAN44-1-4 Drum 1 Minimum Bail Limit Switch CAN 92-5-16 DPF Regen Initiate (N1)
CAN44-1-8 Drum 2 Minimum Bail Limit Switch CAN92-5-32 Engine Run/Start (N1)
CAN44-1-64 Counterweight Pins Extend (Remote) CAN92-5-128 Boom Hoist (Drum 4) Park Switch
CAN44-1-128 Right Counterweight Cylinder Retract (Remote) CAN92-6-2 Free Fall Enable Switch Drum 2
CAN84-2-64 Block-Up Limit 2 - Upper Point (N20) CAN92-6-4
Display 1 (N1)
CAN84-2-128 Block-Up Limit 1- Lower Point (N20) CAN92-6-16
Display 2 (N1)
CAN84-4-32 Minimum Jib Angle Limit (N20) CAN92-6-32 Swing Park Switch
CAN84-4-64 Maximum Jib Angle Limit (N20) CAN92-6-64
Display Exit Switch (N1)
CAN84-4-128 Block-Up Limit 3 - Fixed (N20) CAN92-6-128
Load/Luffing (Drum 3) Park Switch (N1)
CAN85-2-64 Block-Up Limit 3 (N21) CAN113-4-32 Boom Shorting Plug
CAN85-2-128 Block-Up Limit 4 (N21)
CAN92-3-4 Front Drum (Drum 1) Park Switch (N1)