EasyManuals Logo

Maxcess FIFE D-MAXE 2 User Manual

Default Icon
95 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #77 background imageLoading...
Page #77 background image
TROUBLESHOOTING 10 - 8
D-MAXE with OI-TSwww.maxcessintl.com MI 2-292 1 C
Fehlersuche.fm
Possible causes for faulty
behavior
Remedy Reference
Incorrect results in
displays or with web width
measurements.
The measurement range is not
set or is set incorrectly.
Check the measurement range
of the sensors and/or encoders
you are using.
see item
1y.5.1.1.3 Field of
View, page 713
(Sensor) or
item
1y.5.1._.2 Travel Length,
page 716
(Encoder) in section
1y.5 Hardware
For further information see the
"Supplementary Operating
Instructions" in the system
documentation
.
The length unit is set
incorrectly.
Check the length unit.
see item
1y.6.5 Unit, page 720
in section
1y.6 Control