“4069RT” Service and Parts Manual March 2014
Page IX
E
MERGENCY
S
YSTEMS
AND
P
ROCEDURES
IF THE CONTROL SYSTEM FAILS WHILE THE PLATFORM IS ELEVATED, HAVE
AN EXPERIENCED OPERATOR USE THE EMERGENCY LOWERING PROCEDURE
TO SAFELY LOWER THE PLATFORM.
DO NOT ATTEMPT TO CLIMB DOWN ELEVATING ASSEMBLY.
E
MERGENCY
S
TOP
Figure 1-3: Emergency Stop Buttons
The machine is equipped with an EMERGENCY STOP
switch at the base controls and at the platform control box.
Press the EMERGENCY STOP switch at any time to stop all
machine functions.
Turn switch clockwise to reset.
S
ELECTOR
S
WITCH
SET
TO
PLATFORM
Either switch will stop all machine functions.
Both switches must be reset or machine will not operate.
S
ELECTOR
S
WITCH
IS
SET
TO
BASE
The upper controls are locked out.
The lower controls switch must be reset or the machine will
not operate.
The machine will not operate from the lower controls if the upper controls switch is tripped.