EasyManua.ls Logo

Milesight UG63 - Page 26

Milesight UG63
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
Client ID
Client ID is the unique identity of the client to the server.
It must be unique when all clients are connected to the same
server, and it is the key to handle message at QoS 1 and 2.
--
Connection
Timeout/s
If the client does not get a response after the connection
timeout, the connection will be considered as broken. The
Range: 1-65535
30
Keep Alive
Interval/s
After the client is connected with the server, the client will
send heartbeat packet to the server regularly to keep alive.
Range: 1-65535
60
User Credentials
Enable
Enable user credentials.
Username
The username used for connecting to MQTT broker.
Password
The password used for connecting to MQTT broker.
TLS
Enable
Enable the TLS encryption in MQTT communication.
Mode
Select from “Self signed certificates”, “CA signed server certificate”.
CA signed server certificate:verify with the certificate issued by
Certificate Authority (CA) that pre-loaded on device.
Self signed certificates: upload the custom CA certificates, client
certificates and secret key for verification.
Topic
Data Type
Data type sent to MQTT broker.
Topic
Topic name of the data type using for publish.
QoS
QoS 0 Only Once
This is the fastest method and requires only 1 message. It is also the
most unreliable transfer mode.
QoS 1 At Least Once
This level guarantees that the message will be delivered at least once,
but may be delivered more than once.
QoS 2 Exactly Once
QoS 2 is the highest level of service in MQTT. This level guarantees that
each message is received only once by the intended recipients. QoS 2 is
the safest and slowest quality of service level.
Table 3-2-2-4 MQTT Settings Parameters

Other manuals for Milesight UG63