30
Pellerin Milnor Corporation
END FORMULA #03
0 NO
Appears if T=0 in previous display and this is not the last avail-
able step in this formula.
0
No. Aborts the previous T=0 selection. Display returns to the T
(type of step) decision.
1
Yes. Accepts that the formula ends here.
03 D E
02 x
Determine how this formula should end.
0
Stopped. The basket coasts to a stop. After the appropriate end-
of-formula delay, the signal sounds. The signal continues to sound
until the operator presses
.
1
Reversing. After the last step, the basket coasts to a stop, then be-
gins reversing at wash speed while the signal sounds. The basket
continues reversing with the signal on until the operator presses
to silence the signal and end the formula.
2
Drain speed. After the last step, the basket coasts to a stop, then
accelerates to drain speed while the signal sounds. The basket
continues turning at drain speed with the signal on until the opera-
tor presses
to silence the signal and end the formula.
3
Tumble. After the last step, the basket coasts to a stop, then be-
gins reversing at wash speed. After two minutes of tumbing, the
signal sounds. The basket continues tumbling at wash speed with
the signal sounding until the operator presses
to end the
formula.
4
Stopped with 2-minute buzzer. This option is similar to the 0=
Stopped option, but the signal shuts off after two minutes. The
door unlocks after a delay. The operator can end the formula be-
fore this time expires by pressing
.
5
Reversing with 2-minute buzzer. This selection is similar to 1=
Reversing, but the signal shuts off and the basket stops after two
minutes. The door unlocks after a delay. The operator can press
to end the formula before this time expires.
6
Drain speed with 2-minute buzzer. This option is similar to op-
tion 2=Drain speed, except the signal shuts off after sounding for
two minutes. The door unlocks after a delay. The operator can end
the formula before this time expires by pressing
.
7
Tumble with 2-minute buzzer. This option is similar to 3=Tum-
ble, except the signal starts when reversing stops and sounds for
two minutes, then shuts off. The door unlocks after a delay. The
operator can end the formula before this time expires by pressing
.
Programming