Pellerin Milnor Corporation 37
Table 6 Controllers Capable of Transferring Memory (cont'd.)
Machine
Controller
Typical Machine
Models
Controller Software
Later Than
Processor Board Later
Than
E-P Plus
®
30015V_J, 36026V_J,
42026V_J
WUV7J1B/2200K
08BH18EPDT REV. K
30015H_J, 30022H_J
WUH7J1A/2200E
30022X_J
all versions
CAUTION: Configuration data will be overwritten. — When transferring data from
one machine to another, the formulas and configuration data of the Master
machine will be written to the Slave machine. Partial memory transfer is
not possible.
� Record all configure data from the Slave machine before beginning the
download, especially “Offset Height.” Restore this value to the Slave ma-
chine after the download is finished.
� For best results both machines in a machine-to-machine transfer must be identical
models with identical options and controller software, and industry configuration (e.g.,
36026V6J with steam, hot and cold water; software version WUV7J1B/2200K; and con-
figured for Commercial Laundry facilities).
NOTICE: For data transfer to succeed, the processor boards on all included washer-ex-
tractors must have the Milnor part number specified in Table 6: Controllers Capable of
Transferring Memory, page 36 with the specified software installed.
• The Milnor part number for the processor board appears on a white sticker near the Milnor
logo on the processor board.
• The revision level of the processor board is white lettering stamped directly on the green cir-
cuit board, located below the part number sticker. Look for “REV. K.”
• The processor board software version appears on a white label affixed to one of the large inte-
grated circuit components on the processor board.