Chapter 7 Maintenance
164
4
Clean the NCU.
• Wipe off any ink and dust adhering using a cleaning stick moistened with maintenance liquid. Wipe
off the maintenance liquid. Make sure none remains.
• Insert the cleaning stick as far as the line shown in the illustration.
5
Once cleaning is complete, close the cover, then press the [ENTER] key.
Automatic Correction Sensor (DAS) Cleaning
The DAS sensor is located on the carriage underside. If dust or debris accumulates on the sensor, an error
may occur in the automatic correction function (Automatic correction of drop position).
1
On the LOCAL mode screen, select [MENU] > [Maintenance], then press the [ENTER] key.
• The Maintenance menu is displayed.
2
Select [Station Maint.] > [Carriage Out] > [Move To Maint. Space], then press the [ENTER] key.
• The carriage moves to the maintenance space.
3
Open the maintenance cover on the left side.