Chapter5 Troubleshooting
5-12
SYSTEM HALT
An error occurred in the main PCB
FROM.
• Turn off the main power to the machine and
turn it on after a while.
• If the same error message appears again,
contact your local distributor to call for ser-
vice.
An error occurred in the power supply of
the HCB PCB.
• Turn off the main power to the machine and
turn it on after a while.
• If the same error message appears again,
contact your local distributor to call for ser-
vice.
An error was detected in the HCB PCB.
An error was detected in the HCB PCB
communication.
An error was detected in the waveform
being printed.
A failure to update the HCB PCB was
detected.
An error occurred in the HCB board fan.
• Turn off the main power to the machine and
turn it on after a while.
• If the same error message appears again,
contact your local distributor to call for ser-
vice.
An unknown error was detected from the
HCB board.
An abnormality was detected from the
head built-in memory.
An error occurred in the communication
between the HCB board and the slider P
board.
Message Solution
• Turn off the main power to the machine and turn it on after a while.
If the same error message appears again, check the number and contact your local dis-
tributor to call for service. (“000” is the error No.)
• Perform cleaning around the wiper.
• Turn off the main power to the machine and turn it on after a while.
If the same error message appears again, check the number and contact your local dis-
tributor to call for service.
Message Cause Solution
ERROR d01
HCB POWER [1234]
ERROR d02
HCB COMMON [1234]
ERROR d08
HCB UKNWN [1234]
ERROR d09
HD MEMORY [1234]
SYSTEM HALT (*)
000 : MESSAGE
SYSTEM HALT (*)
406 : WIPER ORG