Chapter5 Troubleshooting
Sensor sensitivity adjustment has failed.
Check the state of the nozzles, and if there
are frequent nozzle missing and ink droplet
misalignment, conduct cleaning to restore.
If the same error message still appears after
restoring the state of the nozzles, contact
our service desk or your local distributor to
call for service.
The NCU ink pat is full.
Contact our service desk or your local dis-
tributor to call for service.
THE sensitivity level of the NCU sensor
is low.
Replacement of the NCU is recommended.
Contact our service desk or your local dis-
tributor to call for service.
The sensitivity level of the sensor cannot
be adjusted.
The thermistor connection of a heater is
defective.
Turn off the main power to the machine and
turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
The temperature abnormality of the
heater has been detected.
When this error occurred and if the tem-
perature abnormality cannot be
resolved, the power supply of the
machine is forcibly turned off.
Turn off the main power to the machine and
turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
Power of optional drying heater is not
turned on.
Please make sure this unit and the optional
heater is properly connected.
Detect abnormal temperature of the
optional drying heater.
Connection of the optional drying heater
can not be confirmed.
Cover of the optional drying heater is
open.
Due to a certain error, the function can-
not be performed.
Return to the local screen, check the error
status and take a countermeasure.
There remains received data that has
not yet been printed.
Execute the data clear function. ( P.2-19)
An error occurred in the mounted heads.
Turn off the main power to the machine and
turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
The media width or the media length
required for printing is not enough.
Change the media to the one with enough
width or length.
When the media width narrows because the
origin moved, slide the origin to the right to
widen the effective media width.
The head height setting saved in the
machine and the current head height do
not match.
Set the head height. ( P.2-4)
Message Cause Solution
ERROR 656
NCU SN ADJST
ERROR 657
REPLACE NCU INK PAD
ERROR 658
NCU SENSOR LV LOW
ERROR 65b
NCU Sens Adj Err H
ERROR 65c
NCU Sens Adj Err L
ERROR 702
THERMISTOR CONNECT
ERROR 710
HEATER TEMP ERROR
ERROR 71b
FAN HEATER ERROR
ERROR 901
INVAILD OPERATION
ERROR 902
DATA REMAIN
ERROR 90d
NO HEAD SELECT
ERROR 90f
PRINT AREA SHORT
ERROR 91a
ADJUST HEAD HEIGHT