Chapter5 Troubleshooting
5-10
Pump sensor detection error
Turn the main power OFF, wait a while, and
then turn it ON again.If the same error mes-
sage appears, contact our service desk or
your local distributor to call for service.
The carriage control origin is not set.
Contact our service desk or your local dis-
tributor to call for service.
The station control origin is not set.
An error was detected in station opera-
tion.
Turn the main power OFF, wait a while, and
then turn it ON again.If the same error mes-
sage appears, contact our service desk or
your local distributor to call for service.
An error was detected in cleaning solu-
tion shutter operation.
Ink end (cannot be used, can only be
used when cleaning with the 4-color ink
set)
Replace with new ink.
The ink pack IC chip cannot be correctly
read.
Make sure that the cartridge is ink IC chip
inserted.
Reinsert the ink IC chip.
Turn the main power OFF, wait a while, and
then turn it ON again.If the same error mes-
sage appears, contact our service desk or
your local distributor to call for service.
There is a slot in which the ink IC chip
has not been inserted more than a cer-
tain time.
Set a ink IC chip.
A problem has occurred in the ink pack
IC chip information.
The used count has exceeded the pre-
scribed value.
Make sure there is no nozzle clogging.
Remaining ink is 0 in the cartridge (ink
end/ only when the 4-color ink set is
used))
Replace with new ink.
The nozzle check has been suspended
due to some problem.
Turn the main power OFF, wait a while, and
then turn it ON again.
If the same error message appears, contact
our service desk or your local distributor to
call for service.
The NCU unit is not connected.
The NCU sensor sensitivity is too low to
correctly judge nozzle missing.
The nozzle check function cannot be
used.
The NCU needs to be replaced. Contact our
service desk or your local distributor to call
for service.
The NCU cannot correctly recognize the
ink discharge, because there are fre-
quent nozzle missing and ink droplet
misalignment.
Check the state of the nozzles, and if there
are frequent nozzle missing and ink droplet
misalignment, conduct cleaning to restore.
Adjustment of the discharge position to
the NCU has failed.
Message Cause Solution
ERROR 528
PUMP MOTOR SENSOR
ERROR 52f
CARRIAGE ORG
ERROR 530
STATION ORG
ERROR 536
STATION LOCK
ERROR 537
MAINT.WASH SHUTTER
ERROR 602
CARTRIDGE END
ERROR 608
WRONG INK IC
ERROR 627
RE-INSERT CARTRIDGE
ERROR 628
WRONG INK CARTRIDGE
ERROR 63c
INK REMAIN ZERO
ERROR 64C
NCU ERROR
ERROR 650
NCU CONECT
ERROR 651
REPLACE NCU
ERROR 652
NCU NZK CHK (HW)
ERROR 653
NCU NZK CHK (MARK)
ERROR 654
NCU CENTER POS
ERROR 655
NCU FLUSH POS