5-8
Chapter 5 Troubleshooting
Feeding LimitDETECT
The control limit sensor of the media feed-
ing machine was detected.
Check if the media can be fed correctly in
the jog operation.
Lower the position of the tension bar at
the feeding side. Even if you lower the
position, if the same message is dis-
played, contact a distributor in your dis-
trict, our office or our call center.
NCU SENSOR LEVEL LOW The NCU sensor sensitivity is falling.
Replacement of the NCU is recom-
mended.
Contact our service desk or your local
distributor to call for service.
Nozzle Missing
Print Stopped
Because the nozzle check found nozzles
missing, printing was stopped.
Check the nozzle condition. If there is
plenty of deflection and/or nozzle miss-
ing, clean and restore the affected noz-
zles. ( P.2-17)
If the same error message appears, con-
tact our service desk or your local distrib-
utor to call for service.
The nozzle condition can be checked on
the local guidance screen. ( P.3-28)
NCU FLUSH POS
Nozzle check OFF
Because an NCU-related error occurred
during nozzle check, printing was stopped
and the nozzle check function was turned
OFF.
Check the nozzle condition. If there is
plenty of deflection and/or nozzle miss-
ing, clean and restore the affected noz-
zles. ( P.2-17)
If the same error message appears, con-
tact our service desk or your local distrib-
utor to call for service.
NCU CENTER POS
Nozzle check OFF
NCU SN ADJST
Nozzle check OFF
NCU NZK CHK (HW)
Nozzle check OFF
NCU NZK CHK (MARK)
Nozzle check OFF
NCU CONNECT
The NCU unit is not connected.
The nozzle check function cannot be used.
Turn off the main power to the machine
and turn it on after a while.
If the same error message appears, con-
tact our service desk or your local distrib-
utor to call for service.
REPLACE NCU
The NCU sensor sensitivity is too low to
correctly judge nozzle missing.
The nozzle check function cannot be used.
NCU replacement is necessary.
Contact our service desk or your local
distributor to call for service.
REPLACE NCU INK PAD The NCU ink pad is full.
It is necessary to replace the NCU ink
pad.
Contact our service desk or your local
distributor to call for service.
NCU ERROR
Nozzle check OFF
Because an NCU-related error occurred
during nozzle check, printing was stopped
and the nozzle check function was turned
OFF.
Check the nozzle condition. If there is
plenty of deflection and/or nozzle miss-
ing, clean and restore the affected noz-
zles. ( P.2-17)
If the same error message appears, con-
tact our service desk or your local distrib-
utor to call for service.
REPLACE WIPER
Time to replace the wiper on the capping
station
(The number of times of wiping has
reached a specified value.)
Perform [Replace Wiper] in [Station], and
replace the wiper. ( P.4-22)
** NO MEDIA **
Media is not set, or failure of the media
sensor.
After setting the media, please lower the
clamp lever.
If the same error message appears, con-
tact our service desk or your local distrib-
utor to call for service.
Message Cause Solution