5-17
Chapter 5 Troubleshooting
1
2
2
2
5
SYSTEM HALT
ERROR 64c
NCU ERROR
Printing stopped because an error
occurred during the nozzle check.
Turn off the power button to the machine
and turn it on after a while.
If the same error message appears
again, contact your local distributor to call
for service.
ERROR 650
NCU CONNECT
The NCU unit is not connected.
ERROR 651
REPLACE NCU
The NCU sensor sensitivity is too low to
correctly judge nozzle missing.
The nozzle check function cannot be used.
ERROR 652
NCU NZK CHK (HW)
The NCU cannot correctly recognize the
ink discharge, because there are frequent
nozzle missing and ink droplet misalign-
ment.
Check the nozzle condition. If there is
plenty of deflection and/or nozzle miss-
ing, clean and restore the affected noz-
zles. ( P.2-17)
If the same error message appears, con-
tact our service desk or your local distrib-
utor to call for service.
ERROR 653
NCU NZK CHK (MARK)
ERROR 654
NCU CENTER POS
Adjustment of the discharge position to the
NCU has failed.
ERROR 655
NCU FLUSH POS
ERROR 657
REPLACE NCU INK PAD
The NCU ink pat is full.
Contact our service desk or your local
distributor to call for service.
ERROR 658
NCU SENSOR LV LOW
The NCU sensor sensitivity is falling.
Replacement of the NCU is recom-
mended.
Contact our service desk or your local
distributor to call for service.
ERROR 702
THERMISTOR
The thermistor sensor of a heater is defec-
tive.
Turn off the power button to the machine
and turn it on after a while.
If the same error message appears
again, contact your local distributor to call
for service.
ERROR 703
! PRE HEATER BRK
Pre-heater disconnection.
ERROR 703
! EXT HEATER BRK
External heater disconnection.
ERROR 707
!HD HEATER BREAK
A head heater is disconnected.
Turn off the power button to the machine
and turn it on after a while.
If the same error message appears
again, contact your local distributor to call
for service.
ERROR 710
HEATER TEMP ERROR
An abnormal temperature of the heater
was detected.
If the problem is not resolved after the
occurrence of this error, the power to the
machine is forced OFF.
ERROR d01
HCB POWER [1234]
An error occurred in the power supply of
the HCB PCB.
ERROR d02
HCB COMMON [1234]
An error was detected in the HCB PCB.
ERROR d03
HCB HARD [1234]
ERROR d04
HCB CMD [1234]
An error was detected in the HCB PCB
communication.
ERROR d05
HCB WFM [1234]
An error was detected in the waveform
being printed.
ERROR d06
HCB VUP [1234]
A failure to update the HCB PCB was
detected.
Message Solution
SYSTEM HALT (*)
000 :MESSAGE
Turn off the main power to the machine and turn it on after a while.
Check the number and contact your local distributor to call for service.
(“000” is the error No.)