37
Signum 3 Ex
Operation
Operation
e
1�) Switch on the scale�
The automatic self-test
runs� When the weight
readout is shown, the
scale is ready to operate
and automatically set to
zero� With no load on the
platform, you can zero the
weighing platform at any
time by pressing (
2�)
Place empty container
onthe platform�
)
3�) Tare the scale
Note: If the automatic tare
function is enabled, you
do not need to press the
) key� The tare weight is
saved automatically when
you place the container on
the platform�
Wait until a zero value is
displayed together with the
NET symbol (net weight)�
4�) Place packaged sample in
the container (2nd tare
value)�
250
5�) Enter the tare weight
of the packaging in
the current weight unit
using the keypad (in this
example, 250 g)�
)
6�) Save the package weight�
The package tare is added
to the container tare
Read the net weight�
p
7�) Print the results�
G# + 6.433 kg
T + 4.183 kg
PT2 + 0.250 kg
N + 2.000 kg
--------------------
0
8�) Clear the tare memory:
Enter a zero (“0”) using the
keypad�
)
9�) Save the value (0) entered
(tarevalues are cleared; the
display shows the gross value)�
p
10�) Print the results�
G# + 6.433 kg
T + 0.000 kg
N + 6.433 kg
--------------------
Example: