Counting Application Z
Counting Application Z
With the Counting application, you can
determine the number of parts which
each have approximately equal weight�
Characteristics
– Save the reference weight “wRef” from
the weighing platform
– Enter the reference sample weight
“wRef” using the keypad
– Enter the reference sample quantity
“nRef” using the keypad
– Automatic average piece weight
updating
– Activate Info mode with the I key
– Toggle the display between quantity
and weight using the W key
– Dene the level of accuracy (display
resolution) applied when a calculated
reference sample quantity is saved
– Automatic taring of container weight�
Congured in Setup under:
(Autotare 1st weight)
APPL: A.Tare
– Automatic initialization when the
scale is switched on� The indicator is
initialized with the most recently used
values for reference sample quantity
“nRef” and reference sample weight
“wRef�” Congured in Setup under:
(Start app� with last values)
APPL: A.start
– Exit application, delete parameters:
The value of the reference sample
weight in the reference memory remains
active until it is deleted, overwritten or
the application is changed using the
ckey� The reference sample weight
also remains saved after the scale is
turned o�
You can assign dierent functions to
the c key for deleting applications�
When you clear applications, you can
delete either the data stored for all
applications or just selected data stored
for the active application� Configured in
Setup under:
APPl: sel.cf�
(Sel�
CF function key c in
applications)
– Tare function:
1) If you store a tare (weight value)
by pressing the ) key, you can later
enter a tare value manually� The tare
value you enter is added to the stored
tare value� Setting: menu code 3�25�1
(factory setting)
2) A tare value entered manually
overwrites a stored tare value (weight
value)� If you enter a tare value
manually, a tare value (weight value)
stored later overwrites the manually
entered value� Setting: Menu code
3�25�2
Configured in Setup under:
Appl: tare. f: 3.25.
– Restore factory default settings�
Configured in Setup under:
APPL: def.app: 9.1.
Before the quantity on the platform
can be calculated, the average piece
weight (reference sample weight) must
be entered in the application� There are
three ways to enter this value in the
program:
– Calculation:
– Place the number of parts dened as
the reference sample quantity on the
weighing platform and calculate the
average piece weight by pressing the
O key
– Alternatively, using the r key, you
can place any number of parts on the
weighing platform, enter the number
of parts using the keypad, and then
calculate the average piece weight by
pressing the
O key
How the reference weight is calculated
depends on the application setting for
resolution� The value is either rounded
o in accordance with the display
resolution, or saved with 10-fold
or 100-fold resolution, or with the
maximum internal resolution of the
weighing platform�
– Entering a reference sample weight
(i�e�, the weight of one piece) using the
keypad and saving it with the
O key
After initialization, you can use the
connected weighing platform to count
parts�
The initial application values remain
active until deleted by pressing the
ckey or until overwritten by a new
value� They remain saved after the scale
is switched o�