67
Signum 3 Ex
Classification Application W
Totalizing Application s
Totalizing Application s
With the Totalizing application, you
can add weight values to the totalizing
memory� In addition to weight values,
the number of separate values added
to memory is also saved (transaction
counter)�
Characteristics
– Totalize up to 999 individual weights
Save values automatically:
– Simultaneous saving of net values
and calculated values (if available)�
Congured in Setup under: Appl 3:
totaliz: 3.16.
– Save weight values and calculated
values from either Application 1
(for example, Counting, Weighing
in Percent) or Application 2 (Check-
weighing)� Congured in Setup under:
Appl 3:
totaliz: 3.22.
– Current transaction number displayed in
the text line (indicating the transactions
already added)
– Weighing in up to a dened target,
with the totalization memory content
+ current weight displayed in the text
lines
– Save weight values manually or
automatically
– Activate Info mode with the I key
– Automatic printout when value saved
– Automatic taring of container weight�
Configured in Setup under:
appl: a.tare: 3.7.
– Incomplete totalizing routines saved
in battery-backed memory after
Signum
®
3 is switched o� Configured
in Setup under:
Appl: a.start: 3.8.
– You can assign dierent functions to
the c key for deleting applications�
When you clear applications, you can
delete either the data stored for all
applications or just selected data stored
for the active application� Congured in
Setup under:
Appl: sel.cf: 3.24.
(Sel� CF function key c in
applications)
– Tare function:
1) If you store a tare (weight value)
by pressing the ) key, you can later
enter a tare value manually� The tare
value you enter is added to the stored
tare value�
Setting: menu code 3�25�1 (factory
setting)
2) A tare value entered manually
overwrites a stored tare value
(weightvalue)�
If you enter a tare value manually,
atare value (weight value) stored later
overwrites the manually entered value�
Setting: menu code 3�25�2
Congured in Setup under:
Appl
: tare.f: 3.25.
– Restore factory default settings�
Configured in Setup under:
Appl: def.app: 9.1.
The Signum has a totalizing memory
for totalizing individual net and gross
values� Weight values can be saved to
the totalizing memory either manually
or automatically� In Setup under:
Appl 3:
totaliz: 3.16.
– Save value manually by pressing the
O key�
The value taken from the active
platform is added to the value already
saved in totalization memory and the
transaction counter value is increased
by one�
When a value is added manually, the
program does not check whether the
platform has been unloaded since the
last time the O key was pressed�
– Value saved automatically when the
weighing platform is stable and the
dened minimum load is exceeded�
If the dened minimum load is not
exceeded, you can save the item
manually by pressing the O key�
Regardless of these settings, the current
value cannot be saved automatically
unless the platform is unloaded before
the next sample is placed on it� The
weighing platform is considered to be
unloaded when the load is less than
50% of the minimum load�
The number of items added to memory
is displayed in the text line�
Press the
c key to clear the totalizing
memory� A printout is automatically
generated�
With 2 weighing platforms connected,
you can add values from both platforms
to the totalizing memory� The displayed
result is accurately calculated in the
active weight unit�
Example: When you add 1243 g
(determined on a weighing platform
with three decimal places) to 1400 g
(determined on a platform with
1decimal place), the display shows
2643 g�