48
Signum 3 Ex
Counting Application Z
Preparation
§ Turn scale on: Press the e key
§ While all segments are lit, press the
)key
§ Select Setup: Press the k key
repeatedly until appl is displayed
§ Conrm appl: Press the ) key
§ Select the Counting application:
Press the k key repeatedly and
conrm with the ) key
Counting application parameters
3�6� Minimum load for initialization
3�6�1* 1 digit
3�6�2 2 digits
3�6�3 5 digits
3�6�4 10 digits
3�6�5 20 digits
3�6�6 50 digits
3�6�7 100 digits
3�6�8 200 digits
3�6�9 500 digits
3�6�10 1000 digits
3�9� Resolution for
calculation of reference value
3�9�1* Display accuracy
3�9�2 Display accuracy + 1
decimal place
3�9�3 Display accuracy + 2
decimal places
3�9�4 Internal resolution
3�11 Parameter for saving weight values
3�11� 1* With stability
3�11� 2 With increased
stability
3�12� Average piece weight updating
3�12�1 O
3�12�3* Automatic
* = Factory setting
§ Save the settings with the ) key and
exit Setup: Press the ( key several
times�
Parameter for Saving Weight Values
The weight on the platform is saved as
a reference value when the platform
has stabilized� “Stability is defined as
the point at which the fluctuation of
a measured value lies within a defined
tolerance range� The narrower the
tolerance range, the more stable the
platform is at stability”
In Setup menu:
appl1: count: 3.11.
You can dene whether the value is
saved when standard stability is
reached, or only at increased stability
(narrower tolerance range)� If you
select “increased stability, the value
saved for average piece weight will be
more accurate and the results more
reproducible, but the response time of
the weighing platform might be longer
Accuracy of Average Piece Weight
Calculation
The resolution applied for calculating
the reference weight is dened in Setup
under:
Appl1
: count: 3.9.
The resolution for calculating the
reference weight is increased if “+1
decimal place, “+2 decimal places” or
“Internal resolution is selected� With
the “+1 decimal place” setting, the net
value is determined to one additional
decimal place (i�e�, display accuracy
x 10); “+2 decimal places” increases
display accuracy + 100, and so on up
tothe maximum resolution available�
Minimum Load
The minimum load required for
initialization of the weighing platform
is configured in Setup under:
appl1:
count: 3.6.
Once the limit is exceeded by the load,
initialization can begin�
If the load on platform is too light,
thefollowing will occur when you try
tosave a value:
Error code Inf 29 appears,
The weighing platform is not initialized
The preset reference sample quantity is
saved
The minimum load required for
automatic taring of the container
weight on the platform (rst weight)
iscongured in Setup under:
appl
: m.weigh: 3.5.
You can choose from the following
10levels for this setting:
1 digit
2 digits
5 digits
10 digits
20 digits
50 digits
100 digits
200 digits
500 digits
1000 digits
The digits” here refer to the scale
intervals in the connected weighing
platform� If the interval of the
connected platform is 1 g, for example,
and 1000 digits are required, you
must place at least 1000 g (= 1000
intervals) on the weighing platform for
initialization�
Counting Application Z

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Minebea Intec Signum 3 Ex and is the answer not in the manual?

Minebea Intec Signum 3 Ex Specifications

General IconGeneral
BrandMinebea Intec
ModelSignum 3 Ex
CategoryScales
LanguageEnglish

Related product manuals