Signum 3 Ex
Averaging (Animal Weighing) Application V
Averaging (Animal Weighing) Application V
Preparation
§ Turn scale on: Press the e key
§ While all segments are lit, press the
)key
§ Select Setup: Press the k key
repeatedly until appl is displayed
§ Conrm appl: Press the ) key
§ Select the Animal Weighing application:
Press the k key repeatedly and
conrm with the ) key
Application Parameters: Animal Weighing
3� 6� Minimum load for start
3�6�1* 1 digit
3�6�2 2 digits
3�6�3 5 digits
3�6�4 10 digits
3�6�5 20 digits
3�6�6 50 digits
3�6�7 100 digits
3�6�8 200 digits
3�6�9 500 digits
3�6�10 1000 digits
3�18� Start of averaging
3�18�1* Manually
3�18�2 Automatic
3�19� Animal activity
3�19�1 0�1% of animal/object
3�19�2* 0�2% of animal/object
3�19�3 0�5% of animal/object
3�19�4 1% of animal/object
3�19�5 2% of animal/object
3�19�6 5% of animal/object
3�19�7 10% of animal/object
3�19�8 20% of animal/object
3�19�9 50% of animal/object
3�19�10 100% of animal/object
3�20� Auto printout of results
3�20�1* Off
3�20�2 On
3�21� Static display of result after load
removed
3�21�1* Display is xed until
unload threshold
reached
3�21�2 Fixed display until the
c key is pressed
* = Factory setting
§ Save the settings with the ) key and
exit Setup: Press the ( key several
times�
Minimum Load
The minimum load required for
initialization of the averaging routine
isconfigured in Setup under:
appl1
:
anim.wg: 3.6.
Setting a minimum load for averaging
can be especially useful if you congure
automatic start of measurement�
The minimum load required for
automatic taring of the container
weight on the platform (first weight),
or for automatic printout of results,
isconfigured in Setup under:
appl: a.tare: 3.5.
You can choose from the following
10levels for this setting:
1 digit
2 digits
5 digits
10 digits
20 digits
50 digits
100 digits
200 digits
500 digits
1000 digits
The digits” here refer to the scale
intervals in the connected weighing
platform� If the interval of the
connected platform is 1 g, for example,
and 1000 digits are required, you must
place at least 1000 g (= 1000 intervals)
on the weighing platform to start the
averaging routine�
Starting the Measurements
The averaging routine does not begin
until the fluctuation in weight value
remains below a defined threshold
over three consecutive measurements�
The tolerance limit is defined as a
percentage of the animal or object
weight (for example, 0�1%, 0�2%, ���,
50%, 100%), configured in Setup under:
appl1
:
anim.wg: 3.19.
If the Averaging parameter is set to
2%, for example, and the animal or
object weighs 10 kg, measurement
does not begin until the uctuation
in weight value remains below 200 g
during three consecutive measurements�
Display
A calculated average value is shown
continuously on the main display
The! Symbol (indicating a calculated
value) is also displayed
You can toggle between this display to
a readout of the current weight on the
platform by pressing the w key
In the Setup menu, under:
appl1
:
anim.wg: 3.21.
you can select “Display is static until
unload threshold reached” to have the
display switch automatically to the
weight readout when you unload the
weighing platform (i�e�, when the load
is less than half the minimum load)�
The result of the most recent averaging
operation is not saved
If you select “Display is static until
the c key is pressed, the calculated
average remains displayed even after
the weighing platform is unloaded,
until you press the c key to begin
anew measurement�