Chapter 1 Machine Setup
1-13
Internal assembly check Check for
foreign materials on the surface of linear
scale
- Before power on, ensure that there is no oil on the scale
surface.
- Check that there is no scar on the scale surface. If there are,
replace the surface. Flat cable assembly
- Check that the flat cables are assembled with an appropriate
isolation. Where flat cables are not separated properly, the
machine will sound ‘tick tick...’ when moving.
Conveyor status
- Check the conveyor assembly status.
- Check bolt loosening.
- Check the width of conveyor height guide (Spec. 16mm)
- Check breakage or surface status of the mark point (checked by
offset camera). FOV7mm Head Camera Cable
- Vision monitor image of the FOV7 Head Camera might be
unclear as connection of the vision cable (power cable)
connector of the offset camera is loosened by vibration of the
machine.
A cable tie is used to prevent mobility of the connector.
ANC fixation
- Check the ANC motion.
- Check the connection of sensor cable.
- Check for damage to the cable.
- Check that bolts are fixed.
-Check surface of push plate. (change MC-
type) Protecting camera lens from foreign
materials
- Check for foreign materials on the camera lens (prevent vision
error) - Check that the camera lens is clear.
- Check the operation of LED board of the module camera.
Attaching protective rubber for Amp cable
- Attach rubber to protect the power cable fixed to the Y-Axis, X-
axis Gantry from machine vibration.
Check the home sensor position. Check that
tray support has been replaced with a new version