5-12 Mx100/200 Series Operation Manual
2) Click Warming Up of the Utility menu.
3) The Warming-Up dialog box appears.
<Figure 3-5 Warming-up dialog box >
4) Set Speed to 50% and Stop time (msec) 1000 or more in the
Moving Conditions box.
5) In the Options box, choose ‘With TF’ if case tray feeder is attached
or ‘Gantry only’ if not attached.
6) Click the Auto button. The Front gantry carries out a reciprocating
motion between the warming up positions.
7) Check if there is any abnormal noise or vibration during warming up.
Check/Modify Job Program
7. Check the created job program and, if necessary, modify it using the
program editor or the off-line program editor.
The parts pick & place data can be checked according to the following
procedure. See Chapter 6 Starting Programming for further information on job
programming and pick & place data check.
1) Nozzle mounting in ANC: Mount nozzle in the ANC hole according
to the nozzle assignment to ANC determined by optimization of the job
program.

Table of Contents