EasyManua.ls Logo

Mirae Mx200 - Z-Axis Linear Slide Check; Air Filter Check

Default Icon
681 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4 Regular Chec4k- 4-35
Z-axis Linear Slide check
Module: Head
<Precision Head>
Periodic cleaning and greasing is required for the Z-axis Linear
Slide. Carry out cleaning and greasing as follows.
Check Procedure
1. Unplug the machine.
2. Lift the nozzle by hand as far as possible.
3. Wipe grease and dust from the X-axis Linear Slide using a clean
soft cloth.
4. Apply a thin layer of grease along the longitudinal direction of the
linear slide.
Air Filter check
Module: Cover
Linear Slide Bloc
k
Linear Slid
e