Chapter 4 Regular Chec4k- 4-31
x Checking the separation between rack and pinion
1. Unplug the machine.
2. Check the separation between the rack and pinion gears
while moving the nozzle shaft up and down.
- Normal: There is no shaking even if the nozzle shaft is jerked up and down.
-Abnormal: The nozzle shaft shakes when it is jerked up and
down.
3. If shaking occurs due to improper separation between rack and pinion, it should
be readjusted by service personnel.
Contact the Mirae Customer Support Team.
x Rack & Pinion greasing
-The same as the procedure for greasing the module head.
x Rack & Pinion separation checking
- The same as the procedure for checking the module head
separation.