Operation and Maintenance
Event message Trigger condition
Details
63
Severity
Connection to IP
remote management
(SRM) failed
IP remote management connection
set up (SRM = Secure IP Remote
Management) has failed.
Cause parameter:1: Connection
attempt failed, 2: Authentication
failed, 3: File upload rejected
Cause, date, time Normal (negative,
with match)
Connection to IP
remote management
(SRM) restored
IP remote management connection
has been (SRM = Secure IP
Remote Management) successfully
restored.
Date, time Normal (positive,
with match)
Connection to PMS
system established
A connection with a hotel
management system (PMS
system) has now been successfully
established.
Date, time critical (positive,
with match)
Connection to PMS
system failed
An unsuccessful attempt was made
to establish a connection with a
hotel management system (PMS
system).Reason: 1: Call rejected,
2: Destination unobtainable, 3:
Destination busy, 4: Connection
timeout, 5: Wrong address, 6:
Unknown error
Error, date, time critical (negative,
with match)
CPU2 applications
card Data
communication out of
service
Data communications with the
CPU2 applications card have been
interrupted for an unusually long
period of time (> 1 hour) due to an
error (after a Windows update or
for other reasons).
Date, time critical (negative,
with match)
CPU2 applications
card Data
communications back
in service
Data communications with
theCPU2 applications card have
been restored.
Date, time critical (positive,
with match)
63
The node is also always indicated in an AIN.
Release 7.1
225 System Manual for Mitel SMB Controller