91
Transfers a backed up file as is. The origin data is
replaced.
A backed up file is transferred. However, as for the
origin data and the parameters for recovering
positions, the information inside the controller is
retained.
[
Change robot arm serial number] Valid only when [All Files] or [Parameter Files] is selected under [Backup].
If checked : Replaces serial number of the robot arm in the robot controller with the contents of the
mechanical parameter file to be transferred.
If not checked : A backed up file is transferred. However, the serial number of the robot arm is retained the
information inside the controller.
[Restore file manager’s data] Valid only when [All Files] is selected under [Backup].
If checked : The files stored in the NG folder are transferred, and will be replaced.
If not checked : The files stored in the NG folder are not transferred.
[Restore Operating Information] Valid only when [All Files] or [Parameter Files] is selected under [Backup].
If checked : Replaces the operating information in the robot controller with the contents of the operating
information to be transferred.
If not checked : The backed up operating information files are not transferred.
[Restore maintenance forecast data] Valid only when [All Files] or [Parameter Files] is selected under
[Backup].
If checked : Replaces the information on the maintenance forecast, preventive maintenance / predictive
maintenance (only for compatible models) in the robot controller with the contents of the
maintenance forecast, preventive maintenance / predictive maintenance files to be
transferred.
If not checked : The backed up maintenance forecast, preventive maintenance / predictive maintenance
(only for compatible models) files are not transferred.
If communication is cancelled during a series of restore processing, please note that the origin data may