FX-20P-E Handy programming panel Program Insert Operation 6
6-2
Insert operation condition
• While the PLC is in the RUN status or while the EPROM cassette is attached, the insertion
operation is disabled (in the online mode.)
Example: Inserting the AND instruction M5 before the step No. 200
PLC
status
RUN:
×
STOP:
✓
Valid memory Inbuilt memory:
✓
RAM cassette:
✓
EEPROM
cassette:
U
EPROM
cassette:
×
I 200
201
202
203
AND
OR
OUT
LD
T 111
C 25
Y 100
X 002
I 200
200
201
202
AND
AND
OR
OUT
M 5
T 111
C 25
Y 100
In the step 4)
I 200
201
202
203
AND
AND
OR
OUT
M 5
T 111
C 25
Y 100
GO
0 02
GO
INS/DEL
AND
M 5
GO
1)
2)
3)
4)
Display example
In the step 7)
In the step 8)
5)
6)
7)
8)
Key operation
STEP
Read function