11BAppendix C: Command Summary 82BAttribute Summary
99
Table 51: Attribute Summary (continued)
Class Code
(hex)
Object
Model
Instance
ID #
(hex)
Attribute
ID #
(dec) Attribute Name
Default
Value Description
Factory
Default
Setting
12 watchdog_
timeout_action
0 Transition to the Timed
Out state.
none
13 produced_
connection_path_
length
6 —
none
14 produced_
connection_path
ARRAY
of hex
USINTS
Default value is
specified by the Poll
Response Setup
Attribute (ID #6) in the
Device Configuration
Object (see page 71).
See Table 31, page 63.
none
15 consumed_
connection_path_
length
0 —
none
16 consumed_
connection_path
Empty No specified default.
An implementation
must choose an
Application Object to
reference by default
and initialize this
attribute accordingly.
none
05
Connection
02
17 production_
inhibit_time
0 Default is no inhibit
time.
none
* Refer to the ODVA “DeviceNet Specification,” Volume II [2], for information on User and Calibration
Mode access.