NICE7000 User Manual 7 Description of Function Codes
- 151 -
36: Service oor switchover
If this signal is active, the time-based service 1 remains valid.
37: Fire emergency oor switchover
The NICE7000 supports two fire emergency floors. Fire emergency floor 1 is the default
one. If this signal is active, the elevator stops at re emergency oor 2.
38: Parking oor switchover
The NICE7000 supports two parking oors. Parking oor 1 is the default one. If this signal is
active, the elevator stops at parking oor 2.
Different parking floors can be set for different time periods. For details, see group F6
parameters.
39: Down collective selective switch
The system starts the down collective selective function when the start time set in group Fd
is reached or this signal is active.
40: Peak service
Within the peak service time set in group Fd, the system starts the peak service when the
number of car calls at the peak service oor exceeds 3 or this signal is active.
41: Fire emergency start signal
In this reghter operation state, the elevator starts running when this signal is active.
It is used when there are special requirements for re emergency running.
42: Back door selection signal 43: Back door forbidden signal
When opposite door control is used, these two signals are used to allow or forbid door 2.
44: Light-load signal 45: Half-load signal
It is used for allocation of elevators in parallel or group mode and nuisance judgment in the
anti-nuisance function.
46: Double door control signal
In opposite door control, if the back door is not forbidden, both doors open if this signal is
active.
47: Motor input
The group control system allocate calls to elevators in energy-saving principle when standby
power supply is used.
Function Code Parameter Name Setting Range Default Unit Property
F5-29
X29 function selection
0: Invalid
4: Safety circuit signal
5: Door lock circuit signal
4 -
F5-30
X30 function selection
5 -
F5-31
X31 function selection
5 -
These parameters are used to set the functions of heavy-current detection input terminals
X29 to X31.