NICE7000 User Manual 5 System Commissioning and Functions
- 95 -
Wiring for parallel control by CAN2
Figure 5-11 Wiring when CAN2 (CN6) is used for parallel control
NICE7000
CN
3
CN6
CN2
24V
CAN+
CAN-
COM
Elevator
1#
Elevator 1#
CAN2 cables for parallel control
CAN2
CAN2
+
-
CAN1+
CAN1-
24V
COM
Mod1+
Mod1-
MCTC-CTB
CN1
24V
Mod+
Mod-
COM
MCTC-HCB
NICE7000
CN3
CN6
CN2
24V
CAN+
CAN-
COM
Elevator
2#
CAN2
CAN2
+
-
CAN1+
CAN1-
24V
COM
Mod1+
Mod1-
MCTC-CTB
CN1
24V
Mod+
Mod-
COM
MCTC-HCB
Elevator 2#
2) Group control
Parameter setting
To use group control, connect the CAN2+ and CAN2- terminals of CN6 on the controllers for
group control.
The following table lists the parameter setting of group control.
Table 5-8 Parameter setting of group control
Function Code
Parameter Name
Setting Range
Setting in Group Control
Fd-00
Number of elevators in
parallel/group mode
3–8
3–8
Fd-01
Elevator No.
1–8
1: master elevator
2–8: slave elevator
Fd-02
Parallel/Group control mode
0–2
2
Address Setting of Physical Floors
The setting principle is the same as that for parallel control.
Assume that there are two elevators in parallel mode. Elevator 1 stops at oor B1, oor
1, oor 2, and oor 3; elevator 2 stops at oor 1, oor 3, and oor 4; elevator 3 stops at
oor B1, oor 1, oor 2, and oor 3. Now, set related parameters and HCB addresses