3. F2: fault reset and fault code display
After you enter the F2 menu, the 7-segment LEDs display "0". You can press the UP
button to change the setting to 1 or 2.
Display "1": If you select this value and press the SET button, the system fault is reset.
Then, the display automatically switches over to the F0 menu.
4. Display "2": If you select this value and press the SET button, the 7-segment LEDs
display the 20 fault codes and occurrence time circularly. You can press the PRG button
to exit.
5. F3: time display
After you enter the F3 menu, the 7-segment LEDs display the current system time
circularly.
6. F4: contract number display
After you enter the F4 menu, the 7-segment LEDs display the user’s contract number.
7. F5: running times display
After you enter the F5 menu, the 7-segment LEDs display the elevator running times
circularly.
8. F6: door open/close control
After you enter the F6 menu, the 7-segment LEDs display "1-1", and the UP and SET
buttons respectively stand for the door open button and door close button. You can
press the PRG button to exit.
9. F7: shaft auto-tuning command input
After you enter the F7 menu, the 7-segment LEDs display "0". You can select 0 or 1
here, where "1" indicates the shaft auto-tuning command available.
After you select "1" and press the SET button, shaft auto-tuning is implemented if the
conditions are met. Meanwhile, the display switches over to the F0 menu. After shaft
auto-tuning is complete, F7 is back to "0" automatically.
If shaft auto-tuning conditions are not met, fault code "E35" is displayed.
10. F8: test function
After you enter the F8 menu, the 7-segment LEDs display "0". The setting of F8 is
described as follows:
- 1: Hall call forbidden
- 2: Door open forbidden
- 3: Overload forbidden
- 4: Limit switches disabled
After the setting is complete, press the SET button. Then the 7-segment LEDs display
"E88" and blink, prompting that the elevator is being tested. When you press PRG to
exit, F8 is back to 0 automatically.