- 201 -
Function Code Parameter Name Setting Range Default Unit Property
FP-01 Parameter update 0–4 0 - ★
It is used to set processing on the parameters.
The values are as follows:
•
0: No operation
•
1: Restore default settings
•
2: Clear fault records
•
3: Restore logic board parameters
•
4: Restore all parameter setting
Function Code Parameter Name Setting Range Default Unit Property
FP-02
User-dened parameter display
0: Invalid
1: Valid
0 - ★
It is used to set whether to display the parameters that are modied.
When it is set to 1, the parameters that are different from the default setting are displayed.
Groups E: Fault Details
Function
Code
Parameter Name Setting Range Default Unit Property
Group E0: 1st fault information
E0-00
1st fault code 0–6299
0 - ●
E0-01
1st fault subcode 0–65535
0 - ●
E0-02
1st fault month and day 0–1231
0 MM.DD ●
E0-03
1st fault hour and minute 0–2359
0 HH.MM ●
E0-04
1st fault logic information 0–65535
0 - ●
E0-05
1st fault curve information 0–65535
0 - ●
E0-06
Speed reference upon 1st fault 0.000–8.000
0 m/s ●
E0-07
Feedback speed upon 1st fault 0.000–8.000
0 m/s ●
E0-08
Bus voltage upon 1st fault 0–999.9
0 V ●
E0-09
Output voltage upon 1st fault 0–999.9
0 V ●
E0-10
Output current upon 1st fault 0–655.00
0 A ●
E0-11
Output frequency upon 1st
fault
0.00–99.99
0 Hz ●
E0-12
Output torque upon 1st fault 0–100
0 % ●
E0-13
Torque current upon 1st fault 0–655.00
0 A ●
E0-14
Output power upon 1st fault 0.00–99.99
0 kW ●
E0-15
Present position upon 1st fault 0.00–300.00
0 m ●