3 Mechanical and Electrical Installation NICE7000 User Manual
- 64 -
controller. For the electrical wiring method, refer to Figure 3-15.
The following gure shows the arrangement of shaft position signals in the shaft.
Figure 3-16 Arrangement of shaft position signals
Leveling plate
(floor N)
L
80 D 200 mm
150 mm
L >
2 x F3-08
Top leveling
position
D
L
150 mm
Up final limit
switch
Up limit
switch
30-50 mm
(V: Rated elevator speed)
Up slow-down switch
Down slow-down switch
Bottom leveling
position
Down limit
switch
Down final
limit switch
3050 mm
L >
2 x F3-08
(V: Rated elevator speed)

Table of Contents