EasyManua.ls Logo

Monarch NICE7000 - Installation of Leveling Signals; Installation Requirements of Leveling Switches

Monarch NICE7000
237 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NICE7000 User Manual 3 Mechanical and Electrical Installation
- 65 -
3.10.1 Installation of Leveling Signals
Leveling signals comprise the leveling switch and leveling plate and are directly connected
to the input terminal of the controller. It is used to enable the car to land at each floor
accurately.
The leveling switches are generally installed on the top of the car. The NICE7000 system
supports the installation of 1−2 leveling switches. The leveling plate is installed on the guide
rail in the shaft. A leveling plate needs to be installed at each floor. Ensure that leveling
plates at all oors are mounted with the same depth and verticality.
The following gure shows the installation of leveling signals
Figure 3-17 Installation of leveling signals
Car
Door zone signal detection
Down leveling signal detection
Up leveling signal detection
Leveling
plate
Leveling
switch
The following table describes the installation requirements of leveling switches
Table 3-23 Installation requirements of leveling switches
Number of
Leveling
Switches
Installation Method
Connecting to Input Terminals of
Controller
Setting of
Function Code
1
Door zone
signal detection
X1
X2
X3
+24 VDC
Door zone
signal
F5-01 = 0
F5-02 = 35
X1
X2
X3
+24 VDC
Door zone
signal
F5-01 = 0
F5-02 = 03