- 96 -
according to the following table.
Table 5-9 Parameter setting example of group control on three elevators
Elevator 1 Elevator 2 Elevator 3
Number of
elevators in
parallel/group
mode (Fd-00)
3 3 3
Elevator No.
(Fd-01)
1 2 3
Actual
oor
Physical
oor
HCB
address
HCB display HCB address HCB display
HCB
address
HCB display
B1 1 1 FE-01 = 1101 / / 1 FE-01 = 1101
1 2 2 FE-02 = 1901 2 FE-02 = 1901 2 FE-02 = 1901
2 3 3 FE-03 = 1902
Non-stop oor
but leveling
plate required
FE-03 = 1902 3 FE-03 = 1902
3 4 4 FE-04 = 1903 4 FE-04 = 1903 4 FE-04 = 1903
4 5 / / 5 FE-05 = 1904 / /
Bottom oor
(F6-01)
1 2 1
Top oor (F6-00)
4 5 4
Service oor (F6-
05)
65535
65531 (not stop at physical
oor 3)
65535
•
Wiring for group control by CAN2
Figure 5-12 Wiring when CAN2 (CN6) is used for group control
5.5.3 Opposite Door Control
The NICE7000 implements opposite door control through Modbus communication port. Hall