8 Troubleshooting NICE7000 User Manual
- 204 -
Chapter 8 Maintenance and Troubleshooting
8.1 Maintenance
8.1.1 Routine Maintenance
DANGER
Never perform wiring at power-on. Cut off all power supplies and wait for at least ten minutes so
that the residual voltage on capacitors can discharge safely.
The inuence of the ambient temperature, humidity, dust and vibration will cause the aging
of the components inside the controller, which may cause potential faults or reduce the
service life of the controller. Therefore, it is necessary to carry out routine and periodic
maintenance.
Routine maintenance involves checking:
Whether abnormal noise exists during motor running
Whether the motor vibrates excessively
Whether the installation environment of the controller changes
Whether the cooling fan works properly
Whether the controller overheats
Routine cleaning involves:
Keep the controller clean all the time.
Remove the dust, especially metal powder on the surface of the controller, to prevent
the dust from entering the controller.
Clear the oil stain on the cooling fan of the controller.
8.1.2 Periodic Inspection
Perform periodic inspection on the items that are difcult to check during running. Periodic
inspection involves:
Check and clean the air lter periodically.
Check whether the screws become loose.
Check whether the controller is corroded.
Check whether the wiring terminals have arc signs.
Carry out the main circuit insulation test.