NICE7000 User Manual 4 Use of the Commissioning Tools
- 73 -
12. FA: auto-tuning
After you enter the FA menu, the 7-segment LEDs display "0". The setting of FA is as
follows:
- 0: No function
- 1: With-load auto-tuning
- 2: No-load auto-tuning
- 3:PMSM parameter identication
After the setting is complete, press the SET button. Then the 7-segment LEDs display
"TUNE", and the elevator enters the auto-tuning state. After conrming that the elevator
meets the safe running conditions, press the SET button again to start auto-tuning.
After auto-tuning is complete, the 7-segment LEDs display the current angle for 2s, and
then switch over to the F0 menu.
You can press the PRG button to exit the auto-tuning state.
4.2 Use of the LED Operation Panel
The LED operation panel is connected to the RJ45 interface of the controller by using an
8-core at cable.
Figure 4-3 Connection between the operation panel and the NICE7000
MCTC-PG
NICE7000
MF.K
RUN
STOP
RES
QUICK
PRG
ENTER
RUN
LOCAL / REMOT FED / REV TUNE / TC
RPM
%
A VHz
RJ45
LED operation panel
You can modify the parameters, monitor the working status and start or stop the controller
by operating the operation panel. The following gure shows the LED operation panel.