5 System Commissioning and Functions NICE7000 User Manual
- 80 -
If the input voltage exceeds the allowable value, serious damage will be caused. Distinguish the
negative and positive of the DC power supply. Do not run the system when there is input power
phase loss.
4. Check the grounding.
1) Check that the resistance between the following points and the ground is close to
innity.
- R, S, T and PE
- U, V, W and PE
- 24V and PE on the MCB
- Motor U, V, W and PE
- +, – bus terminals and PE
- Safety circuit, door lock circuit, and inspection circuit terminals and PE
2) Check the grounding terminals of all elevator electrical components and the power
supply of the control cabinet
5.1.2 Trial Running
Trial Running at Inspection Speed
The following gure shows the motor auto-tuning process.
Figure 5-2 Motor auto-tuning process