NICE7000 User Manual 3 Mechanical and Electrical Installation
- 45 -
3.4.2 MCTC-HCB-R1 (Ultrathin Dot-Matrix Display Board)
Figure 3-6 Appearance, dimensions, and installation method of HCB-R1
4-Φ3.5
56.0
134.0
144.0
22.8
39.0
CN1
J1
UP DOWNST XF
70
MCTC-HCB-R1
Unit: mm
6.7
10
MCTC-HCB-R1
1
2
1 - Plastic support higher than 1 cm
2 - Self-tapping screw 4-φ4.9x30
The following table describes the input and output terminals.
Table 3-7 Input and output terminals of HCB-R1
Terminal
Name
Function Terminal Wiring
UP
Interface for the up call button and indicator
Pins 2 and 3 are for up call input. Pins 1 and 4 are power
supply for the up call indicator (24 VDC output, load
capacity: 40 mA).
1 2 3 4
Up call indicator
Up call
button
DOWN
Interface for the down call button and indicator
Pins 2 and 3 are for down call input. Pins 1 and 4 are
power supply for the down call indicator (24 VDC output,
load capacity: 40 mA).
1 2 3 4
Down call indicator
Down call
button
XF/ST
Interface for the re emergency and elevator lock
switches
Pins 1 and 2 are for elevator lock input. Pins 3 and 4 are
for re emergency input.
1 2 3 4
Fire
emergency
input
Elevator
lock
input
J1
Terminal for setting the oor address.
Short J1, and press the UP button or DOWN button to
set the oor address (range 0–56). After the jumper cap
is removed, the address is automatically stored.