EasyManua.ls Logo

Monarch NICE7000 - Fire Emergency Floor Arrival Signal Feedback; Brake and RUN Contactors Healthy; Fault State; Running Monitor

Monarch NICE7000
237 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 Description of Function Codes NICE7000 User Manual
- 152 -
The functions 0, 4, and 5 can be repeatedly allocated to terminals. If X29 to X31 are not
used, cancel the setting of these parameters.
Function Code Parameter Name Setting Range Default Unit Property
F5-32 Y1 function selection
0–22
1 -
F5-33 Y2 function selection 2 -
F5-34 Y3 function selection 3 -
F5-35 Y4 function selection 4 -
F5-36 Y5 function selection 0 -
F5-37 Y6 function selection 0 -
F5-38 Y7 function selection 0
F5-39 Y8 function selection 0
F5-40 Y9 function selection 0
These parameters are used to set the functions of output terminals Y1 to Y9.
Note that Y7 to Y9 are specialized for the NICE7000, and share a common point.
00: Invalid
The terminal has no function.
01: RUN contactor control 02: Brake contactor control 03: Shorting door lock circuit
contactor control
The terminal with one of these functions controls whether the contactor is opened or closed.
04: Fire emergency oor arrival signal feedback
In the re emergency state, the system sends the feedback signal for monitoring after the
elevator stops at the re emergency oor.
05: Door machine 1 open 06: Door machine 1 close 07: Door machine 2 open
08: Door machine 2 close
The terminal with one of these functions is used to control open and close of door 1 or 2.
09: Brake and RUN contactors healthy
When the brake and RUN contactors operate properly, the system sends the feedback
signal for monitoring.
10: Fault state
The terminal with the function has output when the system is in the level-3, level-4 or level-5
fault state.
11: Running monitor
The terminal with the function has output when the controller is running.
12: Shorting PMSM stator contactor
When the shorting PMSM stator contactor is applied in synchronous motor, the terminal with
the function is used to control whether the contactor is closed or opened. For details, see

Table of Contents

Related product manuals