NICE7000 User Manual 3 Mechanical and Electrical Installation
- 41 -
Mark Terminal Name Function Description
Terminal
Arrangement
CN6 Ai-M
Load cell signal
input
0–10 VDC
CN6
Ai
M
24V
CN3
P24
24 VDC power
supply
DI common terminal
CN3
X1
X2
X3
X4
X5
X6
X7
X8
P24
P24
X1 Light curtain 1
DI terminal
1. Photocoupler isolation,
unipolarity input
2. Input impedance: 3.3 kΩ
X2 Light curtain 2
X3 Door open limit 1
X4 Door open limit 2
X5 Door close limit 1
X6 Door close limit 2
X7
Full-load signal
(100%)
X8
Overload signal
(110%)
CN4
B1-BM Door open signal 1
Relay output terminal
Contact drive capacity:
30 VDC, 1 A
CN4
D2
D1
DM
C3
C3M
C2
C1
CM
B3
B2
B1
BM
B2-BM Door close signal 1
B3-BM Forced door close 1
C1-CM Door open signal 2
C2-CM Door close signal 2
C3-C3M Forced door close 2
D1-DM Up arrival signal
D2-DM Down arrival signal
CN5
A-AM (NC
contact)
B-AM (NO
contact)
Car fan and lamp
control
Relay output terminal
Contact drive capacity:
250 VAC, 3 A or 30 VDC, 1 A
CN5
A
B
AM
CN7/CN8
DB9-pin interface
for communication
with the CCB
Connecting the MCTC-CCB
1 2 3 4 5
6 7 8 9
CN7/CN8
CN10 RJ45 interface
Connecting the external
operation panel
CN10
J2
CTB address
jumper in parallel
control
Setting the CTB addresses:
Short OFF or do not connect
the terminal for a single
elevator and master elevator
in parallel control. Short ON for
the slave elevator in parallel
control.
J2
ON
OFF

Table of Contents