A.2.2 G392-020 to G392-072, air-cooled
Designation
Technical data
G392-020
G392-024
G392-032
G392-045
G392-060
G392-072
Output motor side
1)
Voltage 3-phase U
Netz
Rated current effective (l
n
) 20A 24A 32A 45A 60A 72 A
Peak current
see
TableA.2
see TableA.3
Rotating field frequency 0 ... 400Hz
Output stage switching
ferquency
4, 8, 12, 16kHz
Input mains supply side
Mains voltage (3x230V/ 3x400V/ 3x460V/ 3x480V) ±10%
Device connected load
1)
(with mains choke)
13.9kVA 16.6kVA 22.2kVA 31kVA 42kVA 50kVA
Current
1)
(with mains choke) 21.6A 26.2A 34.9A 45A 60A 72A
Asymmetry of the mains voltage ±3%maximum
Frequency 50/60Hz ±10%
Power loss at I
N
1)
400W 475W 515W 610W 830W 1010W
1) Values related to a mains voltage of 3x400V
eff
and a switching frequency of 8kHz
3) Connection of an ext. braking resistor is not permitted for devices with int. braking resistor (version G392-xxx-xxx-xx2)!
Table A.8 Technical data G392-020 to G392-072, air-cooled
Designation
Technical data
G392-020
G392-024
G392-032
G392-045
G392-060
G392-072
DC link
Capacity 1230µF 2000µF 430µF 900µF
Brake chopper switch-on treshold
1)
650VDC
1)
820VDC
Minimum ohmic resistance of
an externally installed braking
resistor
3)
20Ω
3)
12Ω
3)
18Ω 13Ω
Brake chopper continuous power
with external braking resistor
1)
21kW
1)
35kW
1)
37kW 52kW
Peak brake chopper chopper with
external braking resistor
1)
21kW
1)
35kW
1)
37kW 52kW
Optional: internal braking resistor
90Ω
-
Brake chopper continuous power
mit internem Bremswiderstand
see section 3.15.2 -
Peak brake chopper chopper with
internal braking resistor
see section 3.15.2 -
1) Values related to a mains voltage of 3x400V
eff
and a switching frequency of 8kHz
3) Connection of an ext. braking resistor is not permitted for devices with int. braking resistor (version G392-xxx-xxx-xx2)!
Table A.8 Technical data G392-020 to G392-072, air-cooled
NOTE: For further information on brake chopper switch-on threshold please
refer to chapter3.15.