MSDServoDrive AC-AC Operation Manual
moog
9
Id. no.:CA65642-001 Date:03/2012
[ Safety ]
to the glossaryto the table of contents
1 Safety
1.1 Measures for your safety
The following information must be read before initial commissioning to avoid physical
injury and/or material damage. The safety regulations must be strictly observed at any
time.
Read the Operation Manual first!
• Follow the safety instructions!
• Please observe the user information!
Electric drives are generally potential danger sources:
• Electrical voltages 230 V AC to 680VDC
Even 30 minutes after switching off the mains supply
dangerously high voltages of ≥ 50 V may still be present
(capacitor charge). Therefore check for isolation from
supply!
• Rotating parts
• Hot surfaces
Protection against magnetic and/or electromagnetic fields during
installation and operation.
• For persons with pacemakers, metal containing implants and hearing
aids etc. access to the following areas is prohibited:
− Areas in which drive systems are installed, repaired and operated.
− Areas in which motors are assembled, repaired and operated.
Motors with permanent magnets are sources of special dangers.
NOTE: If there is a necessity to access such areas a decision from a physician
is required.
Your qualification:
• In order to prevent personal injury or material damage, only
personnelwith electrical engineering qualifications may work on the
device.
• The qualified person must become familiar with the operation manual
(see IEC364, DINVDE0100).
• Knowledge of national accident prevention regulations (e.g. BGVA3 in
Germany)
During installation follow these instructions:
• Always comply with the connection conditions and technical
specification.
• Comply with the standards for electrical installation, such as wire cross-
section, PE-conductor and ground connection.
• Do not touch electronic components and contacts (electrostatic
discharge may destroy components).
Table 1.1 Notes on safety